Official summary usual Description Procedure codes possible Additional codes Explanations job-related RVU total RVU
Spinal puncture, lumbar, diagnostic, comprehensive 53 (Discontinued procedure) 62270 62270 - 1.37 62270 - 2.25
ventricular puncture; because that implanting ventricular catheter, push recording device, or various other intracerebral monitoring device" data-order="Twist drill hole(s) for subdural, intracerebral, or ventricular puncture; for implanting ventricular catheter, press recording device, or other intracerebral security device" > twist drill hole(s) because that subdural, intracerebral, or ventricular puncture; for implanting ventricular catheter, press recording device, or various other intracerebral monitoring an equipment Ventriculostomy; EVD; ICP screen +61107 +61781 - neuronavigation +61107 - 4.99 +61107 - 9.27
reservoir, EEG electrode(s), push recording device, or other cerebral monitoring device (separate procedure)" data-order="Burr hole(s); for implanting ventricular catheter, reservoir, EEG electrode(s), press recording device, or various other cerebral monitoring device (separate procedure)" > Burr hole(s); for implanting ventricular catheter, reservoir, EEG electrode(s), push recording device, or other cerebral monitoring maker (separate procedure) +61210 +61781 - neuronavigation Ventriculostomy, outside ventricular drain (EVD) through burr feet +61781 - 3.75" data-order="+61210 - 5.83; +61781 - 3.75" > +61210 - 5.83; +61781 - 3.75 +61781 - 6.96" data-order="+61210 - 10.91; +61781 - 6.96" > +61210 - 10.91; +61781 - 6.96
Reprogramming that programmable cerebrospinal shunt +62252 Shunt programming, add if programmable valve to be programmed at the moment of location of valve +62252 - 0.74 +62252 - 2.46
Notes: (For radiological supervision and interpretation, use 75809)" data-order="Puncture of shunt tube or reservoir for aspiration or injection procedure Notes: (For radiological supervision and also interpretation, use 75809)" > Puncture of shunt tubing or reservoir for aspiration or injection procedure Notes: (For radiological supervision and interpretation, usage 75809) Shunt tap 61070 61070 - 0.89 61070 - 1.66
Ommaya Reservoir Placement, Cranial - finish TREATMENT plan 61210; 61215 +61781 61210 - burr hole and ventriculostomy; 61215 - Ommaya reservoir placement; +61781 - neuronavigation 61215 - 5.85; +61781 - 3.75" data-order="61210 - 5.83; 61215 - 5.85; +61781 - 3.75" > 61210 - 5.83; 61215 - 5.85; +61781 - 3.75 61215 - 14.86; +61781 - 6.96" data-order="61210 - 10.91; 61215 - 14.86; +61781 - 6.96" > 61210 - 10.91; 61215 - 14.86; +61781 - 6.96
second repair the dura for cerebrospinal fluid leak, anterior, center or posterior cranial fossa complying with surgery the the skull base; by totally free tissue graft (eg, pericranium, fascia, tensor fascia lata, adipose tissue, homologous or fabricated grafts) 61618 +62272 61618 - repair of posterior fossa CSF leak; +62272 - lumbar drain placement 62272 - 1.35" data-order="61618 - 18.69; 62272 - 1.35" > 61618 - 18.69; 62272 - 1.35 62272 - 2.43" data-order="61618 - 37.73; 62272 - 2.43" > 61618 - 37.73; 62272 - 2.43
Notes: (For intracranial neuroendoscopic ventricular catheter placement, use 62160)" data-order="Creation of shunt; ventriculo-peritoneal, -pleural, other terminus Notes: (For intracranial neuroendoscopic ventricular catheter placement, usage 62160)" > creation of shunt; ventriculo-peritoneal, -pleural, various other terminus Notes: (For intracranial neuroendoscopic ventricular catheter placement, usage 62160) new VP shunt placement 62223 +61781 +62252 - CANNOT usage THIS SHUNT VALVE PROGRAMMING password AT TIME OF location OF VP SHUNT +61781 - 3.75" data-order="62223 - 14.05; +61781 - 3.75" > 62223 - 14.05; +61781 - 3.75 +61781 - 6.96" data-order="62223 - 30.54; +61781 - 6.96" > 62223 - 30.54; +61781 - 6.96
Notes: (For intracranial neuroendoscopic ventricular catheter placement, usage 62160)" data-order="Replacement or review of cerebrospinal liquid shunt, obstructed valve, or distal catheter in shunt device Notes: (For intracranial neuroendoscopic ventricular catheter placement, usage 62160)" > replacement or revision of cerebrospinal liquid shunt, obstructed valve, or distal catheter in shunt device Notes: (For intracranial neuroendoscopic ventricular catheter placement, usage 62160) 62230 +62252 fluid shunt, obstructed valve, or distal catether; +62252 - include if programmable valve to be used and also programmed at the moment of location of valve" data-order="62230 - replacement or review of cerebrospinal liquid shunt, obstructed valve, or distal catether; +62252 - add if programmable valve to be used and programmed at the time of placement of valve" > 62230 - instead of or review of cerebrospinal liquid shunt, obstructed valve, or distal catether; +62252 - include if programmable valve to be used and programmed at the time of location of valve +62252 - 0.74" data-order="62230 - 11.43; +62252 - 0.74" > 62230 - 11.43; +62252 - 0.74 +62252 - 2.46" data-order="62230 - 24.60; +62252 - 2.46" > 62230 - 24.60; +62252 - 2.46
Reprogramming of programmable cerebrospinal shunt VP shunt reprogramming 62252 62252 - 0.74 62252 - 2.46
remove of complete cerebrospinal fluid shunt system; there is no replacement VP shunt removal there is no replacement 62256 +61210 - ventriculostomy through burr hole VPS Removal without replacement +61210 - 5.83" data-order="62256 - 7.38; +61210 - 5.83" > 62256 - 7.38; +61210 - 5.83 +61210 - 10.91" data-order="62256 - 17.51; +61210 - 10.91" > 62256 - 17.51; +61210 - 10.91
remove of complete cerebrospinal liquid shunt system; with replacement by comparable or other shunt in ~ same procedure VP shunt removal v replacement 62258 61781 - neuronavigation; 62160 - use of endoscope to be used and programmed at the time of placement of valve" data-order="62258; 62160; +62252 - include if programmable valve was used and also programmed at the time of location of valve" > 62258; 62160; +62252 - include if programmable valve was used and programmed at the time of location of valve 62160 - 3.00; 61781 - 3.75" data-order="62258 - 15.64; 62160 - 3.00; 61781 - 3.75" > 62258 - 15.64; 62160 - 3.00; 61781 - 3.75 62160 - 5.63; 61781 - 6.96" data-order="62258 - 32.75; 62160 - 5.63; 61781 - 6.96" > 62258 - 32.75; 62160 - 5.63; 61781 - 6.96
VPS complete Revision 62258; 61781 62258; +61781 - Neuronavigation 61781 - 3.75" data-order="62258 - 15.64; 61781 - 3.75" > 62258 - 15.64; 61781 - 3.75 61781 - 6.96" data-order="62258 - 32.75; 61781 - 6.96" > 62258 - 32.75; 61781 - 6.96
Spinal puncture, therapeutic, for drainage of cerebrospinal liquid (by needle or catheter) Spinal Tap, Lumbar drainpipe Placement 62272 62272 - 1.35 62272 - 2.43
Implantation, review or repositioning that tunneled intrathecal or epidural catheter, for permanent medication administration via an external pump or implantable reservoir/infusion pump; without laminectomy 62350 62350 62350 - 6.05 62350 - 11.52
removed of subcutaneous reservoir or pump, formerly implanted because that intrathecal or epidural infusion 62365 62365 62365 - 3.93 62365 - 8.60
Laminectomy with drainage that intramedullary cyst/syrinx; to peritoneal or pleural space 63173 62252 63173; +62252 - add if programmable valve was used and also programmed at the moment of location of valve +62252 - 0.74" data-order="63173 - 24.31; +62252 - 0.74" > 63173 - 24.31; +62252 - 0.74 +62252 - 2.46" data-order="63173 - 50.06; +62252 - 2.46" > 63173 - 50.06; +62252 - 2.46
CSF Leak repair Without Laminectomy 63707; 69990 63707; 69990 69990 - 3.46" data-order="63707 - 12,65; 69990 - 3.46" > 63707 - 12,65; 69990 - 3.46 69990 - 6.43" data-order="63707 - 26.77; 69990 - 6.43" > 63707 - 26.77; 69990 - 6.43
CSF Leak Repair through Laminectomy 63709; 69990 63709; 69990 69990 - 3.46" data-order="63709 - 15.65; 69990 - 3.46" > 63709 - 15.65; 69990 - 3.46 69990 - 6.43" data-order="63709 - 32.02; 69990 - 6.43" > 63709 - 32.02; 69990 - 6.43
Lumboperitoneal Shunt 63741 63741 63741 - 9.12 63741 - 19.69
Lumboperitoneal Shunt review 63744 63744 63744 - 8.94 63744 - 19.27