In a cooling bike of a refrigeration system, warmth is absorbed by the vapor refrigerant in the evaporator adhered to by the compression that the refrigerant by the compressor. The high pressure and high temperature state of the vapor refrigerant is then converted to liquid at the cond. It is designed to condense efficiently the compressed refrigerant vapor.

You are watching: What is the purpose of the condenser


There room basically three species of condensing unit depending upon how the warmth is removed by the condensing tool which is normally water, wait or a combination of both.

Air-Cooled types room usually supplied in the residential and tiny offices applications. Castle are used in small capacity systems listed below 20 tons. The advantages of making use of this architecture include not having actually to perform water piping, not vital to have water handle system, saving in water costs and also not lot scaling problems caused by the mineral content of the water. It is also easier to install and also has lower initial cost. There isn"t much maintenance problems.The disadvantages room that that requires greater power per ton that refrigeration, has much shorter compressor life and on job when most cooling is required, the the very least is available. 


*
A condensing unit that includes finned coils, fan and also compressor.
*
Though aesthetically no pleasant, many installers use aluminium duct come redirect the warm air far from the condenser.

The circulation the air-cooled type can be by natural convection or by required convection (usually making use of blower or fan). Because of its minimal capacity, natural convection is used in smaller applications such as freezers and also refrigerators. In required convection, wait is circulated by making use of a pan or blower that pulls the atmospheric air v the finned coils. Internally, the refrigerant circulates through the coil and also air flows throughout the exterior of the tubes.Water-Cooled
 There are 3 varieties commonly being used. They are shell and also tube, shell and also coil, and twin tube. The most frequently used is the shell and tube type and are usually easily accessible from two tons up to pair of hundreds tons. This design has lower power needs per ton of refrigeration and the compressors can last longer compared to the air-cooled type. A water cooling tower is commonly used for greater capacity application.Evaporative type i m sorry is a combination of water and also air-cooled.


*
Two bigger capacity air-cooled condensers being installed in an open up area.

Air-Cooled and also Water-Cooled comparison Summary

Air-cooled type operates at higher head pressure or condensing pressure, hence reducing the capacity of the compressor and also increases the power intake. In general, a 2 hp water-cooled mechanism will require the very same refrigeration together a 3 hp air-cooled system.

See more: What Is 10 Percent Of 30 Dollars ? (10% Off $30) Percent Off Calculator 10% Off 30 Is 27

The maintenance prices of water-cooled type is around three to 4 times the air-cooled type. Air-cooled kind maintenance is usually restricted to regular lubrication the fan and motor bearings. Water-cooled form requires clean from algae and also bacteria. Scale on the tubes are removed by utilizing acid compound. Proper water therapy is also crucial to the operation of the cond.


Share

FacebookTwitterPinterestTumblrRedditWhatsAppMessenger

*

Energy saving Tips       Refrigerant      IAQ      Motors      Humidifier   Cooling fill    Leak Detection     HVAC Scholarships    Filter Drier  HVAC Contests      3D Printing      air Filter      Pumps    AHU   HVAC Manufacturers    Air Conditioner Ratings       RadonSplit AC Brands    Smart Thermostats   DX System